Derwent Group logo - instrumentation, calibration, storage and safety equipment THE DERWENT GROUP
Instrumentation, calibration, storage and safety equipment
montage of Derwent Group products Call direct on +44 (0) 1332 834141 phone
     
Industrial Process Control > Loadcell amplifiers
Kasar 1 Plus load cell amplifier display
 
Kasar 1 Plus load cell amplifier display
Download datasheet
Summary
 
The Kasar 1 Plus is a compact and economical loadcell amplifier which may be further enhanced to satisfy the weigh controller requirements of most batch processing applications.
Description
 
The Kasar 1 Plus has a 65,000 internal count capability and converts 1000 times per second. This enormous dynamic range makes it equally suited to loss in weight, gain in weight or counting scale applications. Calibration of the unit is performed via the 16-digit LCD dot matrix display and membrane keypad. The display includes a backlight to assist visibility in badly lit areas. The system supports a 4-relay output option, which combined with the standard set point entry facility, converts the Kasar 1 Plus to a compact mini-controller. With its motion detect function coupled to the relay option the Kasar 1 Plus makes an ideal lowcost instrument for go or no-go applications. The 4 to 20mA analogue or serial RS232 ouput further enhance the product.
Features
 
Bulkhead Enclosure rated to IP66
Panel Mount Version can be IP66
Excitation for up to four x 350 Ohm loadcells
upto 6 loadcells by request
3000 division scale
16-digit LCD display
Set points
17 selectable scales
Motion detect
Keyboard calibration
65,000 internal counts
Converts 1000 times per second
Selectable update rate
Specification
 
INPUT CIRCUIT
Input range 0.24mV/V to 5mV/V
Excitation 10 volts DC
Internal resolution 16 Bit
Linearity +/- 1LSB in 65,536counts
Zero offset range 0 to +/- 1.6 mV/V
Input filter Programmable
Motion Detection Programmable

HMI
Display type 16 character LCD
Character height 9.3mm
Enhancement LED backlight
Key-Pad 7 key membrane.

SETUP
User selectable scales 0.3000 to 30,000
Display resolution 1 in 3000
Calibration scale Programmable
Minimum increment Programmable
Security 10 char. access code
Programming Via 7 way keypad
Calibration Automatic via keypad

PHYSICAL
Size (Panel Mount) H120 x W175 x D158
(Bulk Head) H200 x W212 x D70
Panel cut out 65.5 x 138.5
Operating temperature -10 to 50 Deg C
Power supply options 110 or 240 volts AC
( Specify with Order ) 12 or 24 volts DC
Output options RS232 serial or RS485
0-10V or 4-20mA
Opto-isolated I/O
For further details, or to discuss your particular requirements, contact us direct by telephone on +44 (0) 1332 834141, by email at enquiries@derwentgroup.com or through our message form.